REPLACEMENT FILTERS · CUSTOM MANUFACTURING

Dust Collector
Filter Cartridges

Replacement and custom-made filter cartridges for industrial dust collection. Match the cartridge body, mounting interface and seal to your equipment, then specify the filter media and dimensions for your process.

Multiple mounting optionsEnd caps and interfaces for different equipment designs.
Media to suit the processFilter media and treatments selected for the dust and operating conditions.
Standard & custom sizesDimensions confirmed against a drawing or sample.
Replacement & OEM supplyCartridges for existing collectors and new equipment.
Industrial dust collector filter cartridges in multiple sizes and end-cap configurations
Cartridge sizes and end-cap configurations for replacement and custom equipment supply.
01

Filter cartridge designs & mounting options

Start with the physical fit. Body shape, end openings and mounting interface describe different parts of a cartridge specification; they can be combined to suit the equipment.

Common cartridge configurations

Common designs include round filter cartridges, square-flange filter cartridges and filter cartridges with six-lug plastic end caps.

Round dust collector filter cartridges

Round filter cartridges showing a closed bottom cap with a central fixing hole and a double-open-ended configuration
SpecificationOpen/OpenOpen/Closed
End-cap configurationBoth end caps openOne open end cap and one closed end cap
Common dimensionsØ352 × 660 mm / Ø324 × 660 mm
Outside diameter × length
Custom dimensionsDiameters and lengths made to order, including 800 mm and 900 mm lengths.
Cellulose/paper filter mediaFilter cartridge lengths up to 1000 mm in our current cellulose/paper range.
Polyester filter mediaAvailable length depends on the filter cartridge design.Long lengths available, including 1500 mm and 2000 mm.
Bottom mounting holeNot applicable: both end caps are open.Typically Ø12 or Ø14 mm; Ø16 mm is also available to suit a larger support rod. Final hole diameter is confirmed against the mounting arrangement.
Mounting methodMatched to the equipment mounting and sealing arrangement.A central threaded rod passes through the bottom end-cap hole and is secured with a nut.

Polyester filter cartridges longer than 1000 mm usually have one open end cap and one closed end cap. Final dimensions, end caps, gaskets and fixing holes are confirmed against the approved drawing.

Square-flange filter cartridges

SpecificationAvailable configurations
End-cap configurationSquare mounting flange with a circular sealing opening and a closed bottom end cap.
Common dimensionsØ324 × 1000 mm — most popular
Followed by Ø324 × 1200, Ø324 × 660 and Ø324 × 1500 mm.
Outside diameter × length; listed in order of demand.
Cellulose/paper filter mediaFilter cartridge lengths up to 1000 mm in our current cellulose/paper range.
Polyester filter mediaPolyester filter cartridges with this flange type are typically available in lengths up to 1500 mm.
End-cap finishZinc-plated or powder-coated.
Mounting & sealingFlange dimensions, opening, gasket and fixing details are matched to the equipment.
Custom optionsFilter cartridge length, flange, gasket and filter media can be specified to suit the application.
Pleated dust collector filter cartridges with zinc-plated square mounting flanges and sealing gaskets

Rectangular-flange filter cartridges

Rectangular-flange dust collector filter cartridges with a close-up of the underside of the metal end cap
SpecificationAvailable configurations
End-cap configurationRectangular metal mounting flange with a circular opening and a perimeter sealing gasket.
Flange dimensions534 × 425 mm
Flange length × width; these are not cartridge body dimensions.
Cartridge height1000 mm
Cellulose/paper filter mediaAvailable with cellulose/paper filter media. Cartridge lengths up to 1000 mm in our current cellulose/paper range.
Polyester filter mediaAvailable with polyester filter media. Media grade and surface treatment are selected to suit the dust and operating conditions.
Mounting & sealingThe flange opening, gasket profile and mounting arrangement must match the existing dust collector.
Ordering informationSend the existing cartridge dimensions, end-cap photos or a drawing, operating conditions and required quantity. Final specifications are confirmed before production.

Filter cartridges with six-lug plastic end caps

Pleated dust collector filter cartridges with six-lug plastic mounting end caps and sealing gaskets
SpecificationAvailable configurations
End-cap configurationSix-lug mounting end cap with a sealing gasket and a closed bottom end cap.
End-cap materialABS or PP plastic for both top and bottom end caps.
Cartridge diameterØ324 mm; this end-cap design is available in one diameter only.
Common dimensionsØ324 × 660 mm and Ø324 × 900 mm
Outside diameter × length.
Cellulose/paper filter mediaFilter cartridge lengths up to 1000 mm in our current range.
Polyester filter mediaFilter cartridge lengths typically up to 1500 mm.
Custom optionsCartridge length and filter media can be selected to suit the application. Mounting and sealing dimensions must match the equipment.

Top-loading filter cartridges with round flanges

SpecificationAvailable configurations
Mounting configurationRound top flange supported on the tube sheet and secured by clamping plates.
Common dimensionsØ324 × 1000 mm
Outside diameter × length.
Cellulose/paper filter mediaCartridge lengths up to 1000 mm.
Polyester filter mediaCartridge lengths up to 1500 mm.
Custom lengthsAvailable within the maximum length for the selected filter media, subject to minimum order quantities.
Installation & replacementInstalled and removed from above the tube sheet on the clean-air side. Allow sufficient overhead clearance for cartridge removal.
Fit confirmationConfirm the tube-sheet opening, flange dimensions, gasket and clamping arrangement before ordering.
Workers lifting a round-flange filter cartridge from above the dust collector tube sheet, showing clamping plates and grounding connections

Conical & cylindrical air intake filter cartridges

Conical and cylindrical air intake filter cartridge sets, including a 1000 mm long open/closed cylindrical cartridge, with support frames and installed assemblies
SpecificationAvailable configurations
ApplicationsInlet air filtration for gas turbines, industrial air compressors and blast furnace blowers.
Filter setOne open/open conical cartridge paired with one open/closed cylindrical cartridge.
The product photo includes a 1000 mm long cylindrical cartridge.
Large setCone: Ø460 / Ø352 × 660 mm.
Cylinder: Ø352 × 660 mm (most common); 1000 mm length also available.
Small setCone: Ø408 / Ø324 × 660 mm.
Cylinder: Ø324 × 660 mm (most common); 1000 mm length also available.
Cone: large / small end outside diameter × length. Cylinder: outside diameter × length.
Filter mediaTypically supplied with cellulose-based filter media.
Mounting arrangementBoth cartridges fit over a common support frame and are secured by an end plate and fastener.
Bottom mounting holeTypically Ø12 or Ø14 mm; Ø16 mm is also available to suit a larger support rod. Confirm the hole diameter against the existing mounting arrangement.
Replacement matchingConfirm both cartridge sizes, end-cap openings, gaskets and mounting interfaces against the original elements or drawings.

Other mounting options & custom configurations

Other designs & mounting interfaces

Additional configurations are available to match different equipment designs. Body shape and mounting interface are specified separately.

Filter cartridges with six threaded mounting studs, circular end caps and sealing gaskets

Six-stud mounting filter cartridges

Mounted below the tube sheet. Six studs pass through matching holes and are tightened with six nuts from above, compressing the top gasket against the underside of the tube sheet.

Check: Stud spacing, thread size, flange dimensions and gasket.

Filter cartridges with slotted metal collars for bayonet twist-lock mounting

Bayonet-mount filter cartridges

The cartridge inserts into a matching mounting base welded to the tube sheet and locks in place with a twist.

Check: Base interface, locking-slot geometry, engagement dimensions and seal fit.

Three-lug filter cartridge mounting flanges secured to a blue tube sheet

Three-lug filter cartridges

Three mounting ears on the top flange provide fastening points around the air opening. The flange and gasket must match the tube-sheet mounting arrangement.

Check: Lug profile, hole spacing, flange dimensions and sealing surface.

Pleated bag filters & small-diameter filter cartridges

Small-diameter pleated filter cartridges for suitable baghouse conversions and replacement in existing dust collectors. Examples include cylindrical and tapered filter cartridges with different mounting end caps. Dimensions and mounting interfaces must be checked against the existing equipment before ordering.

Dimensions & replacement requirements

ApplicationBag-to-cartridge conversions in suitable baghouses, or replacement of existing pleated cartridges with matching interfaces.
Body shapeStraight cylindrical or tapered; selected to suit the dust collector layout.
Typical body diameterCommon small-diameter bag-replacement filter cartridges are approximately Ø125–160 mm. This is not a fixed diameter for every design shown; flange and body dimensions are confirmed separately.
Element lengthPleated bag-replacement filter cartridges are typically 1,000–3,000 mm long, depending on the design. Other replacement configurations follow the existing element dimensions. Custom lengths are subject to manufacturing review and order quantity.
Mounting head & sealMultiple configurations are available. The flange, fixing method and seal must match the tube-sheet opening and seating arrangement.
Media & filtration areaSpecified for the dust and operating conditions. Filtration area depends on the element dimensions and pleat design; it is confirmed with the quotation.
Information for replacementProvide existing bag or element dimensions, tube-sheet opening size, mounting-head photos or drawings, and the required quantity.

Before a bag-to-cartridge conversion: Confirm tube-sheet fit, sealing, element spacing, pulse-cleaning arrangement and removal clearance. Suitability is reviewed for the actual dust and operating conditions.

Structure shown; specification confirmed separately. Photos illustrate cartridge designs and mounting options. Filter media, surface treatments, dimensions and end-cap details are specified for the application and confirmed on the agreed drawing. Appearance alone does not identify the media or its performance.

02

Filter media & functional treatments

Filter media is selected to suit the dust and operating conditions. Options include cellulose (paper), nanofiber-coated cellulose and polyester with a PTFE membrane, with flame-retardant or antistatic grades available for selected applications.

Base mediaSelectable media configurations
Cellulose (paper)
filter media
  • Cellulose (paper)
  • Cellulose (paper) + Nanofiber coating
  • Cellulose (paper) + flame-retardant treatment
  • Cellulose (paper) + antistatic properties
  • Cellulose (paper) + Nanofiber coating + flame-retardant treatment
  • Cellulose (paper) + Nanofiber coating + antistatic properties
  • Cellulose (paper) + flame-retardant treatment + antistatic properties
  • Cellulose (paper) + Nanofiber coating + flame-retardant treatment + antistatic properties
Polyester (PET)
filter media
  • Polyester (PET)
  • Polyester (PET) + PTFE membrane
  • Polyester (PET) + flame-retardant treatment
  • Polyester (PET) + antistatic properties
  • Polyester (PET) + PTFE membrane + flame-retardant treatment
  • Polyester (PET) + PTFE membrane + antistatic properties
  • Polyester (PET) + flame-retardant treatment + antistatic properties
  • Polyester (PET) + PTFE membrane + flame-retardant treatment + antistatic properties

Specify the complete configuration. Nanofiber coating or PTFE membrane, flame-retardant treatment and antistatic properties are specified separately. An antistatic cartridge does not automatically include the other options. Media grade, availability and suitability are confirmed with the quotation.

Media options & selection

Nanofiber-coated cellulose

A paper-based media option for fine, dry dust. The selected grade is specified to suit the dust characteristics and pulse-cleaning requirements.

PTFE-membrane polyester

Polyester filter media with a PTFE membrane for surface filtration. Suitability is checked against the dust characteristics, moisture and operating temperature.

Flame-retardant treatment

Flame-retardant grades are available for selected media. Flame retardancy does not make a filter cartridge fireproof or replace the system’s fire-protection measures.

Antistatic filter media

Polyester options include an aluminium coating, carbon-based conductive material or embedded conductive metal fibers. Paper-based antistatic media uses carbon-based conductive material. The media specification and cartridge grounding arrangement are confirmed for the application.

Antistatic cartridge examples

Photos illustrate media appearance and cartridge construction. Color alone does not identify antistatic performance, filtration efficiency or flame retardancy. Polyester media with embedded conductive metal fibers is also available; it is not pictured here.

High-temperature filter media

Specialty media options include glass fiber, PPS, polyimide (P84) and aramid. Selection depends on the operating temperature, gas composition and moisture conditions.

The allowable operating temperature is confirmed for the complete cartridge, including the media, adhesive, gasket and end caps.

Filter media selected for your application. We manufacture filter cartridges using purchased filter media. Share the dust type, operating temperature, moisture conditions and any filtration, flame-retardant or antistatic requirements. Available grades and combinations are confirmed with the quotation.

03 · COMMON SIZES & CUSTOMIZATION

Common cartridge sizes & custom options

Find a common dimensional configuration below, then select the media and treatments described in Section 02. For replacement cartridges, confirm the complete mounting interface and seal against your existing element or drawing.

Standard-diameter & tapered cartridges

Nominal size (mm)ConfigurationTop end cap / flange (mm)Top opening Ø (mm)Bottom end cap Ø (mm)Bottom fixing hole Ø (mm)Base media
Ø324 × 660Cylindrical, open/openØ324Ø213Ø324—Cellulose / polyester
Ø324 × 660Cylindrical, open/closedØ324Ø213Ø324Ø14Cellulose / polyester
Ø324 × 1000Cylindrical, open/openØ324Ø213Ø324—Cellulose / polyester
Ø324 × 1000Cylindrical, open/closedØ324Ø213Ø324Ø14Cellulose / polyester
Ø324 × 1000Rectangular mounting flange406 × 424Ø213Ø324—Cellulose / polyester
Ø324 × 1200Rectangular mounting flange406 × 424Ø213Ø324—Polyester
Ø352 × 660Cylindrical, open/openØ352Ø241Ø352—Cellulose / polyester
Ø352 × 660Cylindrical, open/closedØ352Ø241Ø352Ø16Cellulose / polyester
Ø352 × 1000Cylindrical, open/openØ352Ø241Ø352—Cellulose / polyester
Ø352 × 1000Cylindrical, open/closedØ352Ø241Ø352Ø16Cellulose / polyester
Ø408 × 660Tapered, open/openØ408Ø293Ø324—Cellulose
Ø460 × 660Tapered, open/openØ460Ø345Ø352—Cellulose

All dimensions are in millimetres. Open/open means both ends have air openings; open/closed means one air opening and a closed bottom with the listed fixing hole. A dash indicates no small bottom fixing hole. For tapered cartridges, the nominal diameter refers to the larger end; rectangular flange dimensions are length × width.

Listed media options follow the common configurations shown. Nanofiber coatings, PTFE membranes, flame-retardant treatments and antistatic options are specified separately; availability is confirmed with the quotation. Matching nominal size alone does not establish replacement compatibility.

Filtration Area & Pleat Design

Cartridges with the same external dimensions can be manufactured with different filtration areas by adjusting the pleat count and depth. For example, Ø352 × 660 mm cellulose cartridges can be supplied with 18, 20, 21 or 23.4 m² of media, while polyester cartridges of the same nominal size typically have approximately 9–10 m². The area can be customized to suit the media and application, subject to design confirmation.

With the same external dimensions and pleat depth, increasing the pleat count adds filtration area but reduces the spacing between pleats. If the spacing is too narrow, dust can accumulate between the pleats, making pulse cleaning and dust release less effective. Filtration area and pleat spacing should therefore be selected together for the dust characteristics and cleaning conditions; a larger area is not always the better choice.

Small-diameter pleated polyester cartridges

Common pleated bag-replacement configurations with plastic or metal end caps. Tube-sheet hole diameter is listed separately from end-cap diameter. Areas below are reference values for the listed designs and can be customized by adjusting the pleat design.

Plastic end caps

Tube-sheet hole Ø (mm)Top cap Ø (mm)Bottom cap Ø (mm)Reference filtration area
for 1 m length (m²)
Reference filtration area
for 2 m length (m²)
Reference filtration area
for 3 m length (m²)
1331421201.53.04.5
1531601402.14.26.3
1591691452.34.66.9
1621691502.34.66.9

Metal end caps

Tube-sheet hole Ø (mm)Top cap Ø (mm)Bottom cap Ø (mm)Reference filtration area
for 1 m length (m²)
Reference filtration area
for 2 m length (m²)
Reference filtration area
for 3 m length (m²)
1271461141.12.23.3
1331521211.53.04.5
1591781442.14.26.3
1621781462.34.66.9

All listed filtration areas are reference values and can be customized to suit the media and pleat design. Final filtration area is confirmed with the quotation.

Need another size or mounting interface?

Custom lengths, end caps, flanges, seals and support structures can be reviewed against a dimensioned drawing or sample. These tables show common configurations and do not cover every cartridge we can manufacture.

For a quotation: Send the cartridge dimensions, clear photos of both ends, the existing part number or equipment model where available, media requirements and quantity. Include dust type, operating temperature and moisture conditions for media selection.

Request a cartridge quotation →
04 · MANUFACTURING CAPABILITIES

Inside our filter cartridge workshop

Our workshop brings together filter-media pleating, metal support-core forming, adhesive dispensing, ultrasonic welding and cartridge assembly. These production facilities support replacement cartridges, custom mounting configurations and OEM supply.

Polyester media pleating in the 7US cartridge workshop

Polyester media pleating

Pleating polyester filter media for cartridge manufacture.

Cellulose media pleating in the 7US cartridge workshop

Cellulose media pleating

Roll-fed pleating equipment for paper-based filter media.

3 m media pleating equipment in the 7US cartridge workshop

3 m media pleating equipment

Wide-format equipment for pleating media used in long filter elements.

Support core forming in the 7US cartridge workshop

Support core forming

Forming cylindrical support cores from perforated or expanded metal.

Automatic adhesive dispensing in the 7US cartridge workshop

Automatic adhesive dispensing

Applying adhesive during cartridge assembly.

Ultrasonic media seam welding in the 7US cartridge workshop

Ultrasonic media seam welding

Joining the longitudinal seam of suitable polyester media.

Ultrasonic band attachment in the 7US cartridge workshop

Ultrasonic band attachment

Attaching retaining bands to the pleated media.

Band end welding in the 7US cartridge workshop

Band end welding

Joining retaining-band ends around the pleated cartridge body.

Polyester cartridge production in the 7US cartridge workshop

Polyester cartridge production

Batch production of pleated polyester filter cartridges.

Cellulose cartridge production in the 7US cartridge workshop

Cellulose cartridge production

Assembly of paper-based cartridges with protective outer mesh.

Flanged cartridge production in the 7US cartridge workshop

Flanged cartridge production

Production of cartridges with rectangular mounting flanges.

Conical air filter cartridge production in the 7US cartridge workshop

Conical air filter cartridge production

Batch assembly of conical air filter cartridges with protective outer mesh.

From filter media to finished cartridges. We process sourced filter media into pleated cartridges with the specified support structure, end caps and seals. Dimensions, filtration area, media configuration and mounting details are confirmed for each order.

05 · CUSTOM & REPLACEMENT ENQUIRIES

Tell us what your filter cartridge needs to fit

Send the details you have. We can help confirm the mounting dimensions, filter media and cartridge configuration before quotation.

Replace an existing cartridge

Photos and measurements help us match the cartridge to your equipment.

  • Existing cartridge part number, collector make and model, or a drawing, where available.
  • Overall length, outside diameter and opening diameter; include both end diameters for tapered cartridges.
  • End-cap design, gasket dimensions and fixing details, such as a centre hole, flange or mounting lugs.
  • Photos of the complete cartridge, both ends and the mounting interface.
  • Current filter media, any required functional treatments and order quantity.

Specify a custom cartridge

Describe the installation and operating conditions so we can discuss a suitable specification.

  • Required dimensions, mounting method or installation drawing.
  • Dust or fume type, process application and any moisture or oil exposure.
  • Normal operating temperature and any short-term temperature peaks.
  • Required media and treatments, such as nanofiber, PTFE membrane, flame-retardant or antistatic options.
  • Target filtration area, where specified, and required quantity.

OEM supply. Private-label branding, cartridge labels and neutral packaging can be discussed for your order. Media, end caps, seals and mounting details are confirmed against the agreed specification.

Not sure which media to choose? Send your operating conditions and existing cartridge details. We can help review the options; filtration area and pleat spacing are considered together with cleaning requirements.